IPS Power Generation — International Power System
IPS data center generator sets
Data Center Continuous Power

Data Center Generator Sets

Data Center Continuous Power, DCCP, is defined as the maximum power an engine generator can deliver continuously to a constant or varying electrical load for unlimited hours in a data center application.

What is DCCP?

Tier III / Tier IV Compatible Ratings

DCCP models are accepted for a Tier III or Tier IV objective at the baseline conditions of 25 °C and an elevation of 110 m above sea level. Unit nameplates must display the DCCP rating to support Tier Certification of Constructed Facility.

Project Confirmation

Per-Project Site Conditions

DCCP applicability should be confirmed per project depending on site ambient temperature, elevation, installation environment, enclosure, remote radiator, exhaust silencer, or optional alternator air filters.

DCCP Models

EMSA / IPS DCCP Engine-Generator Models

Model NumberDCCP Rating (kW)Voltage (V)Engine Mfr.Engine ModelAlternator Mfr.Alternator Model
E BD ST 1110808230/400Baudouin12M26G1100/5STAMFORDS6L1D-E4
E BD ST 15001,100230/400Baudouin12M33G1500/5STAMFORDS7L1D-C
E BD ST 16501,200230/400Baudouin12M33G1650/5STAMFORDS7L1D-C
E BD ST 20001,500230/400Baudouin16M33G2000/5STAMFORDS7L1D-G
E BD ST 25001,800230/400Baudouin20M33G2500/5STAMFORDS7L1D-J
E BD ST 27502,000230/400Baudouin12M55G2750/5STAMFORDS7L1D-K
E CM ST 1100800230/400CumminsKTA38-G14STAMFORDS6L1D-E4
E CM ST 14001,020230/400CumminsKTA50-G3STAMFORDS6L1D-H4
E CM ST 16501,200230/400CumminsKTA50-GS8STAMFORDS7L1D-C
E CM ST 20001,440230/400CumminsKTA50-G23STAMFORDS7L1D-F
E CM ST 22501,624230/400CumminsQSK60-G4STAMFORDS7L1D-G
E CM ST 25001,800230/400CumminsQSK60-G8STAMFORDS7L1D-J
E CM ST 27502,000230/400CumminsQSK60-G23STAMFORDS7L1D-J
E MH ST 19051,388230/400MitsubishiS16R-PTASTAMFORDS7L1D-F
E MH ST 22501,600230/400MitsubishiS16R-PTAA2STAMFORDS7L1D-G
E MH ST 27502,000230/400MitsubishiS16R-PTAW2-ESTAMFORDS7L1D-J

Source: Uptime Institute acceptance letter dated 22 January 2026 (EMSA Jeneratör DCCP Rating, Tables 1 and 2). Baseline conditions: 25 °C ambient, 110 m elevation.

Document

DCCP Document Preview

Data Center Continuous Power

Uptime Institute DCCP Acceptance Letter — Tier III / Tier IV

Issue Date: 2026-01-22
Request

DCCP Model Selection for Your Data Center

Request Technical Review

Partners

Cummins
Perkins
Mitsubishi Generator
Baudouin
Volvo Penta
John Deere
Yanmar
Hyundai Infracore
FPT Powertrain Technologies
Stamford | AvK
Leroy-Somer
Mecc Alte
Deep Sea Electronics
DEIF
EMSA Generator
Cummins
Perkins
Mitsubishi Generator
Baudouin
Volvo Penta
John Deere
Yanmar
Hyundai Infracore
FPT Powertrain Technologies
Stamford | AvK
Leroy-Somer
Mecc Alte
Deep Sea Electronics
DEIF
EMSA Generator